SNMP Write Lock
The SNMP Write Lock switch is located on the back of the iMediaChassis/3. The
SNMP Write Lock switch prevents a new management board from re-configuring the
application module settings (e.g., the status of
features such as LinkLoss, FiberAlert, Force mode,
etc.) made via SNMP on any previous Management
Modules.
NOTE
Leave this switch in the
NORMAL
position during day-to-day operation; the
LOCKED
position should only be used when changing the SNMP management
board.
The SNMP Management Module can be removed and replaced as necessary. Refer
to the SNMP Management Module manual for complete instructions about how to
configure and operate. If an SNMP Management Module is installed, refer to the
LED panel below for indicators of Link, Temperature, Power Supply modules and
other functions.