iMcV-Giga-FiberLinX-II Operation Manual

Pagina 2 - Warranty

6 III - Hardware Configuration Before installing the module in a chassis, there are two features that must be selected using the DIP switches. These

Pagina 3

7 queried by SNMP. As a Remote unit, the iMcV-Giga-FiberLinX-II will respond to requests for management information from an attached Host unit. The

Pagina 4

8 IV - Installation Instructions Each iMcV-Giga-FiberLinX-II module requires two slots in an iMediaChassis or MediaChassis. To install the module i

Pagina 5

9 Assigning IP Information When the iMcV-Giga-FiberLinX-II is installed in an iMediaChassis, you can use UMA to manage your iMcV-Giga-FiberLinX-II wi

Pagina 6

10 Advertising, rather than Force Mode, when connecting to devices that only use autonegotiation. Refer to Port Configuration on page 19 for more in

Pagina 7

11 FiberAlert FiberAlert minimizes the problems associated with the loss of one strand of fiber. Normally when a single strand of fiber is lost, the

Pagina 8

12 Loopback Testing on Remote or Standalone The following functions are available during loopback testing. During loopback testing, management traff

Pagina 9

13 VI - Using Telnet You must assign the iMcV-Giga-FiberLinX-II an IP address before using a Telnet session (this is not necessary when you are using

Pagina 10

14 Basic Device Configuration After running through an initial self test, the prompt: “Press <Enter> for Device Configuration” displays. Press

Pagina 11

15 NOTE After making any modifications to the Saved Values, reboot the unit for your changes to take effect. To reboot, type the word reboot at the

Pagina 12

FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant

Pagina 13

16 (T) - Assigning SNMP Trap Destinations Traps are sent by the manageable device to a management PC when a certain event takes place. To enter a t

Pagina 14 - ** WARNING **

17 (U) - Deleting All SNMP Community Strings To delete all community strings and start over, press U. You will then be prompted, “Are you sure you

Pagina 15 - ** WARNING **

18 Command Description See Page ifstats Displays interface statistics. rmstats Displays RMON statistics. version Displays the firmware and hardw

Pagina 16

19 7. The download progress displays and ends with a successful download message or with an error message. 8. Press Q or F4 to return to the Device-S

Pagina 17

20 Advertise Ctrl–Selective advertising is used in combination with autonegotiation to advertise your selected speed and duplex mode for the DATA and

Pagina 18

21 NOTE Default mode is the factory default and is provided as a starting point from which to configure the iMcV-Giga-FiberLinX-II modules. This mod

Pagina 19

22 Transparent Mode Setup This parameter allows you to use all untagged data as the management domain by entering N, or allows you to define a VLAN I

Pagina 20

23 VLAN Mode Screen When you enter N in the Transparent Mode Setup screen (page 22), the VLAN Mode screen displays: In this screen you can set the

Pagina 21

24 No VLANs are defined allowing only untagged packets to pass through the unit. Port VLAN on OPTICS (or UPLINK) port This parameter allows you to r

Pagina 22

25 must enter Y in the Tags column for both the Optics row and Data row. Enter up to 32 VLAN IDs in the Data VLANs fields, plus one for SNMP. Manag

Pagina 23

Table of Contents FCC Radio Frequency Interference Statement ------------------------------------------------ ii Warranty-----------------------------

Pagina 24

26 Configuration screen, press the space bar, type unit, and press Enter to open the Unit Control Settings screen. In this screen you can view the u

Pagina 25

27 Unit Max FrameSz–enter the maximum frame size on the unit by using the number keys. The valid values are 1518 to 12196. 802.1p Base Pri–set the t

Pagina 26 - ***WARNING***

28 NOTE It is not recommended to set both the RX and TX Bandwidth limits at the same time. Unit RateControl Enable/Disable–enable or disable the ban

Pagina 27

29 Will you define VLAN IDs? When you want to use VLAN traffic with specific tags on any/all of the DATA ports, you will need to disable Transparency

Pagina 28

30 Transparent with Untagged Management Transparent with Untagged Management mode passes tagged traffic between the DATA port and the OPTICS (or UPLI

Pagina 29

31 NOTE The flow of management domain traffic is defined by the DIP switches. For example, if the management DIP switches are on the OPTICS and DATA

Pagina 30

32 Transparent with Tagged Management Transparent with Tagged Management mode passes both tagged and untagged traffic between the DATA port and the O

Pagina 31

33 d. Enter the management tag (VLAN ID) and the priority (optional). Is a VLAN tag required on Management packets? [ Y ] The Management Tag i

Pagina 32

34 Transparent with Extra Tagging (Q-in-Q) Transparent with Extra Tagging mode can add an extra tag to data received on the DATA port. By using Extr

Pagina 33

35 Enter the extra tag VLAN ID (for example, 8) and the Priority (optional). These values must be identical on both iMcV-Giga-FiberLinX-II modules.

Pagina 34 - Management packets? [ N ]

iv Transparent with Extra Tagging (Q-in-Q)-------------------------------------------------- 34 Port VLAN---------------------------------------------

Pagina 35

36 Port VLAN The Port VLAN mode allows you to configure the iMcV-Giga-FiberLinX-II to accept only data tagged with one specific VLAN ID. This mode c

Pagina 36

37 In the SNMP field, type Y. VLAN IDs Priorities Tags Current Saved Current Saved Ports

Pagina 37 - Settings

38 VLAN on OPTIC Port–Configuration To configure this mode, do the following: 1. In the Main Configuration screen, press the space bar and type confi

Pagina 38

39 5. Press S or F3 to save the settings. 6. Type reboot. The iMcV-Giga-FiberLinX-II is now configured to pass only VLAN ID 13 from the OPTICS (or UP

Pagina 39

40 Port VLAN Filter The VLAN filter mode allows you to isolate a segment of the network to only accept data using some or all of the 32 available VLA

Pagina 40

41 Enter up to 32 VLAN IDs in the Data VLANs rows. VLAN IDs can range from 1 to 4094. Only the VLANs in this list will pass through the unit. Data

Pagina 41 - Giga-FiberLinX-II

42 Now the iMcV-Giga-FiberLinX-II is configured to pass only packets with tags containing the VLAN IDs defined in the Data VLANs table. VLAN ID numb

Pagina 42

43 IX - Troubleshooting • If two iMcV-Giga-FiberLinX-II Host/Remote units are not communicating properly, make sure one is a Host (DIP switch #8) and

Pagina 43

44 • To restore the unit to factory default settings, use the cleandb function via the serial port (refer to the Device-Specific Options from the Com

Pagina 44

45 Troubleshooting LinkLoss/FiberAlert/Link Fault Pass-Through The following diagrams show you how the different troubleshooting configurations for t

Pagina 45

1 I - About the iMcV-Giga-FiberLinX-II Overview The iMcV-Giga-FiberLinX-II™ allows network operators to deploy managed Ethernet services, with a full

Pagina 46

46 FX LinkLoss Normally when a fault occurs on the fiber segment of an iMcV-Giga-FiberLinX-II conversion, only the fiber port LEDs on the modul

Pagina 47

47 TX LinkLoss When a fault occurs on a twisted pair segment joining a device to an iMcV-Giga-FiberLinX-II module, the link fault is not detected by

Pagina 48

48 FiberAlert ***WARNING*** Do not enable FiberAlert at both ends. This can cause the fiber link to lock up. When FiberAlert is enabled on

Pagina 49

49 Link Fault Pass-Through

Pagina 50

50 IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020

Pagina 51

51 Serial Port Pinout The iMcV-Giga-FiberLinX-II features a serial port that uses an IBM-compatible DB-9 serial connector. To connect an iMcV-Giga-F

Pagina 52

52 Notes

Pagina 54

54 Notes

Pagina 55 - Pin Signal

55 Safety Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. CE: The produ

Pagina 56

2 The iMcV-Giga-FiberLinX-II module is a double-slot, chassis-mounted module. Compatible chassis include the following: • iMediaChassis series • Med

Pagina 57

19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2007 IMC Networks. All ri

Pagina 58

3 2iView Management Software iView² is the IMC Networks management software designed specifically for the IMC Networks “iMcV” family of modules. It

Pagina 59

4 About Dynamic Host Control Protocol (DHCP) The iMcV-Giga-FiberLinX-II module includes a Dynamic Host Control Protocol d use that (DHCP) client. B

Pagina 60

5 II - LED Operation The following are iMcV-Giga-FiberLinX-II diagnostic LEDs. In this example, the functions for a 1x9 fiber port version (SC fiber